Flush Horizontal Heads
Senju Flush Horizontal Residential Sidewall Heads


K Factor K=4.2 (60.5) Thread Size1/2" NPT Temperature162°F / 72°C
- Solder type
- Ideal for use in wet pipe residential sprinkler systems as per NFPA 13D, 13R, and 13.   
| Part# | Finish | 
|---|---|
| S4423-0411 | White | 
| S4423-0421 | Chrome | 
| S4423-0431 | Black | 
| S4423-0441 | Brown | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
CN Heads
Senju Concealed Heads Compact Conceal Models



K  Factor K=4.9 (70.6) Residential  
Thread Size  1/2" NPT   
Temperature162℉ / 72℃ Sprinkler with 140℉ / 60℃ Cover Plate  
Vertical Adjustment: 3/8 inch (9.5 mm)  
Compact Concealed Head using a 2 3/8” cover plate. Size matters and smaller can be better!
| Part# | K Factor | Type | Temp | 
|---|---|---|---|
| 21 - 0801 | 4.9K | Residential | 162F / 72C | 
| CN Cover Plates Round 2 3/8" Diameter | |||
|---|---|---|---|
| White | Mirror | Black | |
| 140F | S004-0311 | Call | Call | 
| 162F | S004-0312 | ||
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Senju Concealed Heads
Residential Concealed Pendent Sprinklers



- 162°F / 72°C Sprinkler with 140°F / 60°C Cover Plate
- 205°F / 96°C Sprinkler with 162°F / 72°C Cover Plate
- Solder type
- Ideal for use in wet pipe residential sprinkler systems per NFPA 13D, 13R, and 13.
- Standard cover plate is 3-1/4” (83mm) in diameter
- Smaller 2-5/8” (68mm) cover plate and 2-5/8” (68mm) square cover plate are also available
- Cover plates are available in 11 standard finishes and unlimited custom color and pattern finishes
| Residential Heads - K factor | ||||
|---|---|---|---|---|
| Temperature | 3.0 K | 3.7 K | 4.9 K | 5.8 K | 
| 162F | S8361-2801 | S8261-3801 | S8464-1803 | S8561-3901 | 
| 205F | S8361-2806 | S8261-3806 | S8464-1806 | S8561-3906 | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Firestop-Intumescent Silicone

- Intumescent Silicone (expands when exposed to temperatures above 150°C (300°F))
- Self-Seal GG-266 has achieved GREENGUARD GOLD Certification
- Non-sag silicone, Water-resistant before, during, and after cure
- Freeze-thaw stable, Protects your wall & floor openings
- Tested at positive pressure to simulate the pressure differentials that can occur in a fire situation
| Part# | 
|---|
| 506501 | 
Sprinkler System

- General information sign, covering all details of the installed system 
- Aluminum sign for fire sprinkler systems 
- Size 10” x 12” White aluminum, with mounting holes 
- Clear protective coating, remove before installation
| Part# | 
|---|
| 305788 | 
Air Compressor - Tank Mounted


Professional grade Omega air compressors
- Heavy duty single stage compressors
- Belt guard included 
- CSA approved electrical motors 
- Cast iron pump housings
- Flywheel designed for pump cooling 
- Manual reset for overload protection 
- Quiet operation 
- Pressure factory setting 50 – 80 PSI 
- 115 / 1 phase AC voltage 
- Tank size 20 gallons 
- Regulator, gauge and switch included
- Base units are available 
- Other tank sizes, voltages and horse power options available upon request
| Part# | HP @ 90psi | Peak HP | FAD/CFM 125PSI | Volume Imp. Gel | Pump RPM | 
|---|---|---|---|---|---|
| 402000T | 2 | 5 | 7.0 | 650 | 934 | 
Air Compressor - Fire Sprinkler Series


Fire Sprinkler Series, Omega air compressors
- Belt guard included 
- CSA approved electrical motors 
- Cast iron pump housings for durability 
- Pumps supplied with oil sight gauge 
- Flywheel designed for pump cooling 
- Manual reset for overload protection 
- Pressure factory setting 30 - 50 PSI
- Air receiver rated at 200psi and CRN approved 
- 115 volt / 1 phase standard, (230 volt /1 phase optional)
- Quiet operation 
- Tank Size 20 gallons 
- Magnetic starter required 
- Factory mounted options available
--Low oil shutdown with magnetic starter
--Auto drain (electronic or pneumatic) 
--Belt guard after cooler option
| Part# | HP | CFM / FAD @ 35PSI | System Volume Gal | Weight (lbs) | Pump RPM | 
|---|---|---|---|---|---|
| 400500TFS | ½ | 3.1 | 290 | 176 | 485 | 
| 401000TFS | 1 | 6.0 | 550 | 194 | 970 | 
| 402000TFS | 2 | 10.5 | 985 | 203 | 1040 | 
Nitrogen Air Maintenance Device

| Part# | Potter# | 
|---|---|
| 4070901 | NAMD | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Portable Nitrogen Analyzer

The Portable Nitrogen Analyzer is an easy way to determine the purity of nitrogen that the Potter Nitrogen Generator is producing
- One button calibration 
- Maintenance free
| Part# | Potter# | 
|---|---|
| 4070900 | PNA | 
Additional Files
Click on the buttons inside the tabbed menu:
Techanical Informaiton
Other Documents
Nitrogen Generators from Potter

| Part# | System Capacity (litre) | Largest Riser To fill at 40 PSI (276kPa) | Weight | 
|---|---|---|---|
| 4070100N | 2555 | 605 | 59 kg | 
| 4070250N | 3785 | 1135 | 59 kg | 
| 4070600N | 8896 | 1987 | 182 kg | 
Additional Files