Switch – Manual, Single Pole
FURNAS

- Designed for starting and stopping single-phase fractional horsepower motors
- Terminal design – box terminals provide easy access for writing
- Small size – open starter fits GEM or handy box
| Part# | Size | 
|---|---|
| 406552 | Switch/less heaters | 
| 406553 | Heater relay 8.5 amps | 
Water Test Kit

- Have POTTER test the water supply of the sprinkler system
- Meets requirements of NFPA 13, 2002 4.3
- 5 groups of bacteria tested
| Part# | Potter# | 
|---|---|
| 404099 | WTK | 
Additional Files
Click on the buttons inside the tabbed menu:
Sales Sheets
Other Documents
Corrosion Monitoring Station

- Service pressure: up to 250 PSIG
- Temperature range: 40°F to 120°F (4.5°C to 49°C)
- Coupon Holders: Qty. (2) included
- Designed to simulate conditions within the fire sprinkler system
- The coupon rack can be isolated from the fire sprinkler riser and easily accessed for servicing and monitoring of test specimens (corrosion coupons) without interruption to fire protection
| Part# | Potter# | 
|---|---|
| 404042 | PCMS-RM | 
Additional Files
Click on the buttons inside the tabbed menu:
Sales Sheets
Other Documents
Automatic Air Release

- Service pressure: up to 175 PSIG
- Temperature range: 40°F to 120°F (4.5°C to 49°C)
- Air Vent: 1” NPT inlet 3/32” Orifice
- Water Shutoff Valve: Activation indicated by red pop-up tap on the shutoff valve
- Single set of NC contacts rated 24V AC/DC @2A ( contacts open upon activation of shutoff valve) and 6' Lg. Wiring harness supplied for supervision of shutoff valve
| Part# | Potter# | 
|---|---|
| 404091 | PAAR-B | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Pressure Switch – Adjustable Deadband
Potter Flow
 

- The model PCS is an Adjustable Deadband Pressure Switch with independent set and reset points which are adjustable throughout the entire operating range of the switch
- The minimum deadband (minimum span between set and reset points) may be obtained at any point in the operating range of the switch
- A change in pressure greater than the high setting will reposition the switch mechanism to open or close a single snap-action electrical switch
- This control device is designed for use as an operating control in applications sensing air, water, or any fluid not harmful to the pressure connection, diaphragm or nitrile pressure-sealing o-ring.
- Where an operating control would result in personal injury and-or loss of property, it is the responsibility of the installer to add devices (safety, limit controls) that protect against, or systems (alarm, supervisory systems) that warn of control failure
- Not intended for applications in explosive environments or use with hazardous fluids
- Adjustable Pressure Switch
- Minimum deadband: 12 PSIG
- Proof pressure: 400 PSIG
- Factory setting: 90/60 PSIG
| Part# | Potter# | Description | 
|---|---|---|
| 404085 | PCS-300-1B | Single | 
Additional Files
Click on the buttons inside the tabbed menu:
Sales Sheets
Other Documents
Switch – Pressure, Excess Pressure
Potter Flow
 
 

- Pressure actuated switches designed primarily to detect a 10 PSI increase and/or decrease from normal system pressure in automatic fire sprinkler systems
- Typical applications are air pressure supervision in systems with excess pressure
- PS120-1A: Operates on decrease at 110 PSI
- PS120-2A: Operates on increase at 130 PSI and on decrease at 110 PSI
- Pressure Range: 10-175 PSI
| Part# | Potter# | Description | 
|---|---|---|
| 4071120 | PS120-1A | Single | 
| 4071120 - 2A | PS120-2A | Double | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Switch – Pressure, Dry Systems
Potter Flow
 
 

- Pressure actuated switches designed primarily to detect a 10 PSI increase and/or decrease from normal system pressure in automatic fire sprinkler systems
- Typical applications are air pressure supervision in dry pipe systems and pressure supervision of pressure tanks, air supply or water supply
- PS40-1A: Operates on decrease at 30PSI
- PS40-2A: Operates on increase at 50 PSI, and on decrease at 30 PSI
- Pressure Range: 10-175 PSI
| Part# | Potter# | Description | 
|---|---|---|
| 407140 | PS40-1A | Single | 
| 407140 - 2A | PS40-2A | Double | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Switch – Low Pressure, Wet Systems
Potter Flow
 
 

- The Potter PS10A Series Pressure Actuated Switches are designed for the detection of a waterflow condition in automatic fire sprinkler systems of particular designs such as wet systems with alarm check valves or dry pipe systems
- May also be used to provide a low pressure supervisory signal
- They may be adjusted to operate on pressure between 4 and 20 PSI
| Part# | Potter# | Description | 
|---|---|---|
| 407110 | PS10-1A | Single | 
| 407110 - 2A | PS10-2A | Double | 
Additional Files
Click on the buttons inside the tabbed menu:
Other Documents
Key – for Tamper Proof Cover Screws
Switch – Waterflow Alarm
Potter Flow
 
 

- Pressure operated switch with an adjustable, instantly recycling pneumatic retard to prevent false alarms due to water pressure variation
- The EFSR-F is connected into the alarm port of a wet sprinkler system alarm check valve
- Pressure Adjustments: Factory adjusted to operate between 4 and 8 PSI on rising pressure
- Maximum System Pressure: 175 PSI
- Contact Ratings: Two Sets of SPDT (Form C)
| Part# | Potter# | 
|---|---|
| 404076 | WFSR-F | 
Additional Files
Click on the buttons inside the tabbed menu: